125/261 kWh Liquid-Cooled C&I Energy Storage System
One cabinet integrates a 261 kWh LiFePO4 battery and a 125 kW PCS, with full liquid cooling and optional PACK-level fire protection. Plug-and-play and expandable on demand, it serves peak shaving, microgrids and backup power for commercial and industrial users.
Product Overview
System OverviewStandard distributed cabinet design: battery, inverter, AC protection, energy management, thermal control and monitoring are highly integrated. Modular construction is plug-and-play with a short installation period, and standard modules combine for capacity expansion on demand.
Integrated Cabinet
261 kWh battery, 125 kW PCS, metering, monitoring, fire protection and liquid cooling in one cabinet — ready to run once installed.
LFP Battery System
314 Ah high-capacity cells in 1P260S configuration: high safety, long life, 261.248 kWh total energy.
125 kW PCS
Three-level design with constant-voltage, constant-current and constant-power modes, up to 98.5% efficiency, grid-tied and off-grid operation.
BMS + EMS
Two-level BMS (1×BCU + 5×BMU) and modular EMS strategies keep the whole charge/discharge process under control.
Full Liquid Cooling
Zoned cooling with independent circuits; the inverter-driven liquid cooling unit keeps cell temperature within 35 °C.
PACK-level fire protection (optional)
Perfluorohexanone extinguishing agent with two selectable schemes; please specify when ordering.
System Scheme
System SchemeThe WES-125/261 integrates an independent 261 kWh energy storage system: an all-LiFePO4 battery bank built from one 125 kW PCS and 261 kWh of battery capacity. High energy and long charge/discharge capability meet long-duration peak-shaving requirements.
All-in-One Cabinet Solution
The cabinet integrates a 261 kWh battery system (modules, boxes, racks, high-voltage box and a two-level BMS), a 125 kW PCS, an energy metering unit, monitoring, fire protection and a liquid cooling system.
- Battery system 314 Ah LiFePO4 cells, 1P260S, 261.248 kWh total
- Energy storage converter 125 kW PCS (three bridge arms), bidirectional AC/DC conversion
- Energy management EMS controller + station control software
- Auxiliary systems Metering, monitoring, fire protection, 5 kW cooling unit and piping
Bidirectional Conversion · Grid-tied & Off-grid
The PCS uses a three-phase three-bridge-arm topology with single-phase and three-phase active/reactive power control and multi-unit parallel expansion. Communication with the BMS and EMS enables power regulation and charge/discharge management.
- Operating mode Grid-tied / off-grid dual-mode operation
- Power regulation Adjustable active/reactive power, PF -0.99/-1 to 1
- Transfer speed Charge/discharge transfer ≤100 ms
- Safety protection Anti-islanding, AC/DC disconnection and DC reverse-connection protection
Key Specifications
Key SpecificationsBattery System & PCS
Battery System & PCSHigh-safety, long-life large-capacity LFP cells paired with an efficient three-level PCS: battery clusters work fully independently to avoid circulating current, while BMS and EMS manage the whole charge/discharge process.
High-Safety Long-Life LFP Cells
Cell dimensions 173.7×71.7×204.6 mm (L×W×H), weight about 5.60 kg. Battery box: 166.4 V, 314 Ah, 52.249 kWh, about 341.5 kg.
- Cathode material LiFePO4, charge cut-off 3.65 V
- Discharge cut-off 2.5V 0℃≤T≤55℃ · 2.0V -20℃≤T 0℃
- DC internal resistance 0.18±0.05mΩ
- Operating environment Charging 0–60 °C · Discharging -30–60 °C
125 kW Three-Level PCS
Built on 100 kW modules with a three-level design, the PCS offers constant-voltage, constant-current and constant-power modes; zero battery consumption on standby, ≤100 ms transfer time and up to 98.5% efficiency.
- Battery-friendly Clusters operate fully independently, avoiding circulating current and extending service life
- Flexible application Compatible with three-phase three-wire/four-wire systems; the communication bus monitors every module
- Scalability Multi-unit parallel operation for easy expansion
- Grid support L/HVRT, active and reactive power control
Liquid Cooling & Fire Protection
Thermal Management & Fire ProtectionThe pack liquid-cooling system uses zoned cooling, each zone with its own circuit, ensuring even pack temperature and higher pack efficiency; fire protection is offered in two PACK-level schemes (optional).
Thermal management keeps cells within 35 °C for optimum operation.
Cell ΔT within a cluster stays below 3 °C for better consistency and longer life.
Cooling output adapts on demand, balancing temperature accuracy and energy use.
Two PACK-level perfluorohexanone schemes; please specify when ordering.
Zoned Liquid Cooling · All-Weather Control
The thermal system consists of one inverter-driven liquid cooling unit and its piping: when cells run hot, cooler medium is supplied to remove heat; when too cold, warmer medium raises cell temperature, keeping cells in their optimum range.
- Zoned cooling Modules are divided into multiple independent cooling zones
- Independent circuits Each zone has its own coolant loop for tighter control
- Variable frequency Cooling delivered on demand to save energy
- Uniform temperature Even temperature across the whole pack
Fire Scheme 1 · With Host Detection
A five-in-one detector monitors H₂/CO/VOC concentration, smoke and temperature, triggering a non-pressurized perfluorohexanone unit that suppresses fire through piping and nozzles.
Fire Scheme 2 · Independent Type
Independent perfluorohexanone inside the PACK protects the modules; during thermal runaway it spreads across the enclosure faster and isolates air — safer, cleaner and more efficient than alkane or water-based agents.
Application Scenarios
Application FieldsOne cabinet, many uses: from C&I peak shaving to microgrids and backup power; standard modules combine on demand for varied load profiles.
Standards
EXECUTED STANDARDSSupply List
SUPPLY LISTInstallation & Selection
Installation & SelectionReady to deploy: a pre-cast base, reserved service clearance, proper cable routing and fire sealing complete the installation; inspect weekly, monthly and seasonally after handover.
Make Every Kilowatt-Hour Count
The 125/261 kWh liquid-cooled ESS builds in peak shaving, demand control, anti-backflow and backup strategies. Contact us for a system design and quotation.
A wind-solar-storage-charging integrated energy system provider — an industrial, integrated, high-tech group.
Address
- WOLUN New Energy Group Co., Ltd.: Room 2602, 26F, Unit 1, Building 5, No. 8 Liuli Road, Jinjiang District, Chengdu, Sichuan
- Sichuan Wolun Electric Manufacturing Co., Ltd.: No. 108 Tianyuan Street, Xinmin Town, Da'an District, Zigong, Sichuan
Contact
- Group hotline: +86 028-68938363
- Factory hotline: +86 0813-5308858
- Domestic sales: +86 188 2888 5368
- Domestic e-mail: wolunxs@wolungroup.com
- Overseas sales: +86 188 2888 5328
- Overseas e-mail: wolunhw@wolungroup.com
- Aftersales: 400 604 1668