GB 240-480kW Integrated Dual-Gun DC Charger
240/320/360/400/480kW integrated DC charger in five power ratings: dual-gun output, 200~1000VDC wide voltage platform, modular configuration, IP54 outdoor protection, multiple safety protections and intelligent temperature control, compatible with mainstream EV models.
Product Overview
System OverviewThe 240/320/360/400/480kW series DC chargers are independently developed based on years of R&D and equipment operation experience to meet the high-reliability, high-performance and energy-saving requirements of EV DC charging, featuring high system stability and reliability.
Integrated dual-gun structure
Integrated cabinet with dual charging guns, front-door design, floor-mounted ready to use, highly adaptable to outdoor deployment.
Modular configuration
Compatible with mainstream charging modules, flexibly configured by power rating for customized applications.
Intelligent temperature control
The intelligent temperature control system improves energy efficiency and extends component life, with forced-air cooling.
Seamless multi-platform compatibility
High network stability, one-click terminal switching, simplified O&M; Ethernet and 4G communication.
Multiple safety protections
Multiple protection design against overvoltage, undervoltage, overcurrent, leakage, lightning surge, emergency stop, fire and flame retardance.
Multiple optional configurations
Supports optional tilt detection, smoke alarm, water immersion detection, heater and more; exterior color and LOGO customizable.
Technical Highlights
Technical FeaturesModular configuration, intelligent temperature control, multi-platform compatibility and high protection design: a highly reliable DC fast-charging solution for public charging stations, logistics parks, bus depots and more.
IP54 protection rating, highly adaptable to extreme environments, reliable long-term outdoor operation.
High-efficiency rectifier modules deliver lower conversion losses and better energy savings.
200~1000VDC output with constant-power range 300~1000VDC, compatible with mainstream models.
One station, two guns with flexible power dispatch to increase site utilization and revenue.
Eight technical highlights
Independently developed with advanced design technologies to meet the high-reliability, high-performance and energy-saving requirements of EV DC charging systems.
- Modular configuration Compatible with mainstream modules, customized applications, flexible adaptation
- Intelligent temperature control Intelligent temperature control improves energy efficiency and extends component life
- Multi-platform compatibility High network stability, one-click terminal switching, simplified O&M
- High-protection design IP54 protection rating, highly adaptable to extreme environments
- Vehicle-charger adaptation optimized Wide compatibility with mainstream models, future-proofing reserved, high adaptability
- Multiple safety protections Over/under-voltage, overcurrent, leakage, lightning surge, emergency stop, fire and flame retardance
- Multiple options Tilt detection, smoke alarm, water immersion detection, heater and more
- Custom development Exterior color and LOGO customizable to user requirements
Technical Specifications
Technical ParametersTechnical parameters of the GB 240/320/360/400/480kW integrated DC charger are as follows; the five power ratings share one platform, select by site requirements.
Installation Guide
Installation InstructionsThe charger must be installed on a prefabricated base: base height preferably 200mm, length and width not smaller than the cabinet, vertical inclination not exceeding 5%; concrete or channel-steel foundation allowed, mounting surface must be flat.
Outline dimensions
Charger outline dimensions L×W×H = 1110×999×1713mm, front-door design; four-side views and isometric drawing shown below.
- Front height 1713mm (incl. base · body 1680mm)
- Front width 1110mm (body 980mm)
- Side depth 999mm
Cabinet Placement & Base
Embed 4 M12 stainless steel bolts in the mounting surface with threads protruding 40±3mm above ground, or embed 4 M12 (GB/T 22795-2008) sleeve-reinforced expansion bolts; the charger is front-door, so reserve operating space on all sides.
- Base Concrete / channel steel · height 200mm · flat surface
- Anchor bolts M12 × 4 · protruding 40±3mm
- Clearance Sides ≥800mm · Front ≥900mm · Rear ≥100mm
- Vertical inclination Not exceeding 5%
Cable Configuration & Installation Key Points
Cables & Key PointsCommissioning & Maintenance
Commissioning & MaintenancePower-on commissioning must be performed by trained personnel with our technicians notified; maintenance includes routine maintenance, periodic inspection and technical retrofitting, following industry norms and local regulations.
Commissioning
Before power-on, confirm the AC input switch is off, the equipment is reliably grounded, and internal wiring and screws are tightened; measure phase-to-phase and phase-to-ground insulation resistance with a megohmmeter, verify normal three-phase grid voltage with a multimeter, then close the switch to power on.
- Pre-power-on checks Cabinet reliably grounded · wiring screws tightened
- Insulation measurement Measure phase-to-phase and phase-to-ground insulation with a megohmmeter
- Grid verification Multimeter confirms normal three-phase voltage
- Power-on sequence Secondary-circuit leakage breaker → AC input switch
Routine Maintenance & Inspection
Routine maintenance covers four items: charging gun, cabinet, functions and data records; inspection focuses on internal cables, screws, terminals, breakers and power modules, with dust filters cleaned regularly according to environmental dust.
- Charging gun Return to holster to prevent damage · keep dry · no rough dragging
- Cabinet inspection Shell rust or water leakage · screen · indicators · door lock · emergency stop
- Function check Charging function · backend connection · screen operation and version configuration
- Dust-filter interval Near construction sites 15 days · roadside 1 month · stations/residential areas 3 months · underground parking 6 months
Using the emergency stop button
In case of leakage, fire, electric shock or other abnormal conditions, or when the charger malfunctions and charging cannot be stopped or internal wiring is short-circuited, press the emergency stop immediately; it directly cuts off the AC contactor and de-energizes the modules. After the emergency is cleared, rotate the emergency stop switch clockwise to reset.
Operating precautions
In humid weather, confirm the gun head and vehicle socket are dry before charging; do not use the gun or cable if defective, cracked, damaged or exposed; do not unplug directly or move the vehicle during charging; wait until the interface fully switches before unplugging after charging.
Full charge for every journey
GB 240-480kW integrated dual-gun DC charger: modular configuration, multiple safety protections, IP54 outdoor protection. Contact us for station solutions and quotations.
A wind-solar-storage-charging integrated energy system provider — an industrial, integrated, high-tech group.
Address
- WOLUN New Energy Group Co., Ltd.: Room 2602, 26F, Unit 1, Building 5, No. 8 Liuli Road, Jinjiang District, Chengdu, Sichuan
- Sichuan Wolun Electric Manufacturing Co., Ltd.: No. 108 Tianyuan Street, Xinmin Town, Da'an District, Zigong, Sichuan
Contact
- Group hotline: +86 028-68938363
- Factory hotline: +86 0813-5308858
- Domestic sales: +86 188 2888 5368
- Domestic e-mail: wolunxs@wolungroup.com
- Overseas sales: +86 188 2888 5328
- Overseas e-mail: wolunhw@wolungroup.com
- Aftersales: 400 604 1668